KLB flat blocks SW1
Thermal insulation for low-energy and passive houses / Approval Z-17.1-730
KLB flat blocks SW1 correspond to slotted full blocks and are thermal insulation blocks for low-energy houses pursuant to EnEV 2016, energy efficient houses KfW-55, KfW-40 or passive houses. In conjunction with KLB thin-bed mortar, best values of thermal conductivity (λR ≥ 0.10 W/mK) result for this masonry depending on the gross density and strength class. Low energy houses with 36.5 cm thick exterior walls without additional insulation can be built according the requirements of the EnEV with these blocks.
KLB flat blocks SW1 are approved by the German Institute for Construction Technology (DIBt), Berlin, Approval Z-17.1-730.
- SW1 - 24,0 cm
- SW1 - 30,0 cm
- SW1 - 36,5 cm
- SW1 - 42,5 cm
- SW1 - 49,0 cm
Block variety/Block type |
KLB flat blocks SW1 - Z-17.1-730 |
||
---|---|---|---|
Wall thickness |
cm |
24 |
|
Format |
- |
16 DF |
|
Length |
mm |
497 |
|
Width |
mm |
240 |
|
Height |
mm |
249 |
|
Number of chamber/slot rows |
- |
6 |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
4 (5,0) |
Compressive stress σ0 m. DBM |
MN/m² |
0,5 |
0,9 |
Character. Value of compressive strength fk |
MN/m² |
1,5 |
2,7 |
Gross density class |
- |
0,45 |
0,60 |
Calculated weight with DBM |
kN/m³ |
5,5 |
7,0 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,10** |
0,14 |
Thermal resistance RT with DBM |
m²K/W |
2,68** |
1,99 |
U-value*) with DBM |
W/m²K |
0,37** |
0,50 |
Heat storage capacity |
kJ/m²K |
146 |
194 |
Cool down time |
h |
100 |
98 |
Fire resistance, α2 = 1.0, plastered |
- |
F 90-A |
F 90-A |
Fire wall, plastered once |
- |
no |
no |
Block requirements per m² |
piece |
8 |
8 |
Block requirements per m³ |
piece |
33 |
33 |
Mortar requirements per m² |
Liter |
3,0 |
3,0 |
Mortar requirements per m³ |
Liter |
12 |
12 |
Working time reference value full masonry |
h/m³(h/m²) |
1,40 |
1,55 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
1,45 |
1,60 |
Packet/palette content |
piece |
48 |
48 |
Average weight per block 1) |
kg |
17 |
23 |
Article number 40391070 |
- |
36571 |
36717 |
Main field of application 2) |
- |
2; 3 |
2; 3 |
Block variety/Block type |
KLB flat blocks SW1 - Z-17.1-730 |
||||||
---|---|---|---|---|---|---|---|
Wall thickness |
cm |
30,0 |
|||||
Format |
- |
10 DF 20DF |
|||||
Length |
mm |
247 497 |
|||||
Width |
mm |
300 300 |
|||||
Height |
mm |
249 249 |
|||||
Number of chamber/slot rows |
- |
7 7 |
|||||
Tensile strength class (medium tensile strength) |
(N/mm²) |
4 (5,0) |
2 (2,5) |
||||
Compressive stress σ0 m. DBM |
MN/m² |
0,9 |
0,5 |
||||
Character. Value of compressive strength fk |
MN/m² |
2,7 |
1,5 |
||||
Gross density class |
- |
0,60 |
0,45 |
||||
Calculated weight with DBM |
kN/m³ |
7,0 |
5,5 |
||||
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,14 |
0,10 |
||||
Thermal resistance RT with DBM |
m²K/W |
2,42 |
3,28 |
||||
U-value*) with DBM |
W/m²K |
0,41 |
0,30 |
||||
Heat storage capacity |
kJ/m²K |
242 |
203 |
||||
Cool down time |
h |
151 |
175 |
||||
Fire resistance, α2 = 1.0, plastered |
- |
F 90-A |
F 30-A |
||||
Fire wall, plastered once |
- |
no |
no |
||||
Fire wall, plastered twice |
- |
- |
- |
||||
Block requirements per m² |
piece |
16 |
8 |
||||
Block requirements per m³ |
piece |
54 |
27 |
||||
Mortar requirements per m² |
Liter |
3,6 |
3,6 |
||||
Mortar requirements per m³ |
Liter |
12 |
12 |
||||
Working time reference value full masonry |
h/m³(h/m²) |
1,70 |
1,45 |
||||
Working time reference value categorised. Masonry |
h/m³(h/m²) |
1,95 |
1,60 |
||||
Packet/palette content |
piece |
72 |
36 |
||||
Average weight per block 1) |
kg |
14 |
22 |
||||
Article number 40391070 |
- |
35079 |
35109 |
||||
Main field of application 2) |
- |
2, 3 |
2, 3 |
Block variety/Block type |
KLB flat blocks SW1 - Z-17.1-730 |
||
---|---|---|---|
Wall thickness |
cm |
36,5 |
|
Format |
- |
12 DF |
|
Length |
mm |
247 |
|
Width |
mm |
365 |
|
Height |
mm |
249 |
|
Number of chamber/slot rows |
- |
||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
4 (5,0) |
Compressive stress σ0 m. DBM |
MN/m² |
0,5 |
0,9 |
Character. Value of compressive strength fk |
MN/m² |
1,5 |
2,7 |
Gross density class |
- |
0,45 |
0,6 |
Calculated weight with DBM |
kN/m³ |
5,5 |
7,0 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,10 |
0,14 |
Thermal resistance RT with DBM |
m²K/W |
3,93 |
2,89 |
U-value*) with DBM |
W/m²K |
0,25 |
0,35 |
Heat storage capacity |
kJ/m²K |
239 |
288 |
Cool down time |
h |
249 |
218 |
Fire resistance, α2 = 1.0, plastered |
- |
F 30-A |
F 90-A |
Fire wall, plastered once |
- |
no |
no |
Block requirements per m² |
piece |
16 |
16 |
Block requirements per m³ |
piece |
44 |
44 |
Mortar requirements per m² |
Liter |
4,5 |
4,5 |
Mortar requirements per m³ |
Liter |
12 |
12 |
Working time reference value full masonry |
h/m³(h/m²) |
1,60 |
1,65 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
1,85 |
1,90 |
Packet/palette content |
piece |
60 |
60 |
Average weight per block 1) |
kg |
13 |
17 |
Article number 40391070 |
- |
35116 |
35086 |
Main field of application 2) |
- |
2, 3 |
2, 3 |
Block variety/Block type |
KLB flat blocks SW1 - Z-17.1-730 |
||
---|---|---|---|
Wall thickness |
cm |
42,5 |
|
Format |
- |
14 DF |
|
Length |
mm |
247 |
|
Width |
mm |
425 |
|
Height |
mm |
249 |
|
Number of chamber/slot rows |
- |
11 |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
|
Compressive stress σ0 m. DBM |
MN/m² |
0,5 |
|
Character. Value of compressive strength fk |
MN/m² |
1,5 |
|
Gross density class |
- |
0,45 |
|
Calculated weight with DBM |
kN/m³ |
5,5 |
|
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,10 |
|
Thermal resistance RT with DBM |
m²K/W |
4,53 |
|
U-value*) with DBM |
W/m²K |
0,22 |
|
Heat storage capacity |
kJ/m²K |
229 |
|
Cool down time |
h |
275 |
|
Fire resistance, α2 = 1.0, plastered |
- |
F 30-A |
|
Fire wall, plastered once |
- |
no |
|
Fire wall, plastered twice |
- |
- |
|
Block requirements per m² |
piece |
16 |
|
Block requirements per m³ |
piece |
38 |
|
Mortar requirements per m² |
Liter |
5,0 |
|
Mortar requirements per m³ |
Liter |
12 |
|
Working time reference value full masonry |
h/m³(h/m²) |
1,75 |
|
Working time reference value categorised. Masonry |
h/m³(h/m²) |
1,95 |
|
Packet/palette content |
piece |
48 |
|
Average weight per block 1) |
kg |
15 |
|
Article number 40391070 |
- |
36588 |
|
Main field of application 2) |
- |
2 |
Block variety/Block type |
KLB flat blocks SW1 - Z-17.1-730 |
||
---|---|---|---|
Wall thickness |
cm |
49,0 |
|
Format |
- |
16 DF |
|
Length |
mm |
247 |
|
Width |
mm |
490 |
|
Height |
mm |
249 |
|
Number of chamber/slot rows |
- |
13 |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
|
Compressive stress σ0 m. DBM |
MN/m² |
0,5 |
|
Character. Value of compressive strength fk |
MN/m² |
1,5 |
|
Gross density class |
- |
0,45 |
|
Calculated weight with DBM |
kN/m³ |
5,5 |
|
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,10 |
|
Thermal resistance RT with DBM |
m²K/W |
5,18 |
|
U-value*) with DBM |
W/m²K |
0,19 |
|
Heat storage capacity |
kJ/m²K |
259 |
|
Cool down time |
h |
375 |
|
Fire resistance, α2 = 1.0, plastered |
- |
F 30-A |
|
Fire wall, plastered once |
- |
no |
|
Fire wall, plastered twice |
- |
- |
|
Block requirements per m² |
piece |
16 |
|
Block requirements per m³ |
piece |
33 |
|
Mortar requirements per m² |
Liter |
6,0 |
|
Mortar requirements per m³ |
Liter |
12 |
|
Working time reference value full masonry |
h/m³(h/m²) |
1,75 |
|
Working time reference value categorised. Masonry |
h/m³(h/m²) |
1,95 |
|
Packet/palette content |
Stück |
48 |
|
Average weight per block 1) |
kg |
18 |
|
Article number 40391070 |
- |
36700 |
|
Main field of application 2) |
- |
2 |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 20 mm mineral fibre light-weight plaster λR = 0.31 W/mK
**) with DBM "L"
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall,
6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block