KLBQUADRO flat elements
Easy-to-handle large blocks / approval Z-17.1-852
The KLBQUADRO flat elements are large blocks, which are currently not yet regulated in DIN standards. Standard elements (with butt joint interlocks on both sides) in thicknesses of 11.5 cm, 15.0 cm, 17.5 cm, 20.0 cm and 24.0 cm are supplied separately, as are mixed pallets with supplementary formats of length 373 mm and 247 mm as bricks with toothing on both sides or as end bricks with a smooth butt surface on one side, and blocks of length 497 mm as end blocks.
KLBQUADRO flat elements are no longer cut to length or divided at predetermined breaking points, but supplemented by supplementary elements of the same height with lengths of 373 mm and 247 mm. Thanks to these intermediate lengths half-height masonry in 25 cm or 12.5 cm steps is achievable. Non-modular dimensions, offset layer, height and length balance are mostly created using masonry supplementations via existing, statically and acoustically coordinated precision blocks and precision stones, so expensive cuts are generally not required. In addition to the required mini-crane, which can move two blocks at once, the individual KLBQUADRO flat element can also be moved manually by two masons thanks to its manageable size and weight. The wall integrations are handled using butt joint technology per perforated connecting strip in every position. The masonry connection must be mortared interlocking.
The manufacture and use of the KLBQUADRO flat elements is regulated by approval Z-17.1-852.
Product data sheets KLBQUADRO flat element
- 11,5 cm
- 15,0 cm
- 17,5 cm
- 20,0 cm
- 24,0 cm
Type of block |
KLBQUADRO flat elements - Z-17.1-852 |
||
---|---|---|---|
Wall thickness |
cm |
11,5 |
|
Format |
16 DF |
8 DF / 12 DF / 16 DF |
|
Block |
1/1 |
supplementary elements |
|
Length |
mm |
497 |
247/373/497 |
Width |
mm |
115 |
115 |
Height |
mm |
498 |
498 |
Number of chamber/slot rows |
- |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
20 (25) |
20 (25) |
Compressive stress σ0 m. DBM |
MN/m² |
3,2 |
3,2 |
Character. Value of compressive strength fk |
MN/m² |
10,0 |
10,0 |
Gross density class |
2,0 |
2,0 |
|
Calculated weight with DBM |
kN/m³ |
20 |
20 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 |
1,20 |
Thermal resistance RT with DBM |
m²K/W |
0,44 |
0,44 |
U-value*) inner wall with DBM |
W/m²K |
2,26 |
2,26 |
U-value*) outer wall with DBM |
- |
- |
|
Sound Rw *) inner wall single shell |
dB |
53,3 |
53,3 |
Sound Rw **) inner wall two shells |
dB |
71 |
71 |
Fire resistance, α2 = 1.0, plastered |
F 90-A |
F 90-A |
|
Fire wall, plastered once |
no |
no | |
Fire wall, plastered twice |
no |
no |
|
Block requirements per m² |
piece |
4 |
4 |
Block requirements per m3 |
piece |
35 |
- |
Mortar requirements per m² |
Liter |
0,9 |
0,9 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,44)3 |
(0,44)3 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,48)3 |
(0,48)3 |
Packet/palette content |
piece |
32 |
32 |
Packet/palette content m² |
|
8 |
8 |
Average weight per block 1) |
kg |
57 |
57 |
Article number 40391070 |
39107 |
39169 |
|
Main field of application 2) |
6, 7 |
6,7 |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 100 mm mineral fibre light-weight plaster (WLG 035)
**) plastered, onesided with 15 mm gypsum light-weight plaster, with continous 30mm parting line, filled with min. insulation
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block
3) time for m² with offset aid, as blocks are > 25 kg
Type of block |
KLBQUADRO flat elements - Z-17.1-852 |
||
---|---|---|---|
Wall thickness |
cm |
15,0 |
|
Format |
20 DF |
10 DF/15 DF/20 DF |
|
Block |
1/1 |
supplementary elements |
|
Length |
mm |
497 |
247/373/497 |
Width |
mm |
150 |
150 |
Height |
mm |
498 |
498 |
Number of chamber/slot rows |
- |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
20 (25) 20(25) |
20 (25) |
Compressive stress σ0 m. DBM |
MN/m² |
3,2 3,2 |
3,2 |
Character. Value of compressive strength fk |
MN/m² |
10 10 |
10 |
Gross density class |
2,0 2,2 |
2,0 |
|
Calculated weight with DBM |
kN/m³ |
20 22 |
20 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 1,70 |
1,20 |
Thermal resistance RT with DBM |
m²K/W |
0,47 0,43 |
0,47 |
U-value*) inner wall with DBM |
W/m²K |
2,12 2,30 |
2,12 |
U-value*) outer wall with DBM |
0,31 0,32 |
0,31 |
|
Sound Rw *) inner wall single shell |
dB |
56,7 57,8 |
56,6 |
Sound Rw **) inner wall two shells |
dB |
72 72 |
72 |
Fire resistance, α2 = 1.0, plastered |
F 90-A F 90-A |
F 90-A |
|
Fire wall, plastered once |
no no |
no |
|
Fire wall, plastered twice |
no no |
no |
|
Block requirements per m² |
piece |
4 4 |
- |
Block requirements per m3 |
piece |
27 27 |
|
Mortar requirements per m² |
Liter |
1,1 1,1 |
- |
Working time reference value full masonry |
h/m³(h/m²) |
(0,44)3 (0,44)3 |
- |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,48)3 (0,48)3 |
- |
Packet/palette content |
piece |
24 24 |
- |
Packet/palette content m² |
|
6 6 |
6 |
Average weight per block 1) |
kg |
74 82 |
- |
Article number 40391070 |
39305 39329 |
39312 |
|
Main field of application 2) |
6, 7 6, 7 |
6,7 |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 100 mm mineral fibre light-weight plaster (WLG 035)
**) plastered, onesided with 15 mm gypsum light-weight plaster, with continous 30mm parting line, filled with min. insulation
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block
3) time for m² with offset aid, as blocks are > 25 kg
Type of block |
KLBQUADRO flat elements - Z-17.1-852 |
|
---|---|---|
Wall thickness |
cm |
17,5 |
Format |
24 DF |
|
Length |
mm |
497 |
Width |
mm |
175 |
Height |
mm |
498 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
20 (25) 20 (25) |
Compressive stress σ0 m. DBM |
MN/m² |
3,2 3,2 |
Character. Value of compressive strength fk |
MN/m² |
10,0 10,0 |
Gross density class |
2,0 2,2 |
|
Calculated weight with DBM |
kN/m³ |
20 22 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 1,70 |
Thermal resistance RT with DBM |
m²K/W |
0,49 0,45 |
U-value*) inner wall with DBM |
W/m²K |
2,03 2,23 |
U-value*) outer wall with DBM |
0,31 0,32 |
|
Sound Rw *) inner wall single shell |
dB |
58,5 59,8 |
Sound Rw **) inner wall two shells |
dB |
74 75 |
Fire resistance, α2 = 1.0, plastered |
F 90-A F 90-A |
|
Fire wall, plastered once |
yes yes |
|
Fire wall, plastered twice |
yes yes |
|
Block requirements per m² |
piece |
4 4 |
Block requirements per m3 |
piece |
23 23 |
Mortar requirements per m² |
Liter |
1,3 1,3 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,44)3 (0,44)3 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,48)3 (0,48)3 |
Packet/palette content |
piece |
24 24 |
Packet/palette content m² |
|
6 6 |
Average weight per block 1) |
kg |
87 95 |
Article number 40391070 |
39114 39190 |
|
Main field of application 2) |
6, 7 6, 7 |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 100 mm mineral fibre light-weight plaster (WLG 035)
**) plastered, onesided with 15 mm gypsum light-weight plaster, with continous 30mm parting line, filled with min. insulation
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block
3) time for m² with offset aid, as blocks are > 25 kg
Type of block |
KLBQUADRO flat elements - Z-17.1-852 |
|
---|---|---|
Wall thickness |
cm |
20,0 |
Format |
24 DF |
|
Length |
mm |
497 |
Width |
mm |
200 |
Height |
mm |
498 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
20 (25) 20(25) |
Compressive stress σ0 m. DBM |
MN/m² |
3,2 3,2 |
Character. Value of compressive strength fk |
MN/m² |
10,0 10,0 |
Gross density class |
2,0 2,2 |
|
Calculated weight with DBM |
kN/m³ |
20 22 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 1,70 |
Thermal resistance RT with DBM |
m²K/W |
0,49 0,45 |
U-value*) inner wall with DBM |
W/m²K |
2,03 2,23 |
U-value*) outer wall with DBM |
0,31 0,32 |
|
Sound Rw *) inner wall single shell |
dB |
60,2 61,5 |
Sound Rw **) inner wall two shells |
dB |
74 75 |
Fire resistance, α2 = 1.0, plastered |
F 90-A F 90-A |
|
Fire wall, plastered once |
yes yes |
|
Fire wall, plastered twice |
yes yes |
|
Block requirements per m² |
piece |
4 4 |
Block requirements per m3 |
piece |
20 20 |
Mortar requirements per m² |
Liter |
1,3 1,3 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,44)3 (0,44)3 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,48)3 (0,48)3 |
Packet/palette content |
piece |
20 20 |
Packet/palette content m² |
|
5 5 |
Average weight per block 1) |
kg |
87 95 |
Article number 40391070 |
39336 39343 |
|
Main field of application 2) |
6, 7 6, 7 |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 100 mm mineral fibre light-weight plaster (WLG 035)
**) plastered, onesided with 15 mm gypsum light-weight plaster, with continous 30mm parting line, filled with min. insulation
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block
3) time for m² with offset aid, as blocks are > 25 kg
Type of block |
KLBQUADRO flat elements - Z-17.1-852 |
|
---|---|---|
Wall thickness |
cm |
24,0 |
Format |
32 DF |
|
Length |
mm |
497 |
Width |
mm |
240 |
Height |
mm |
498 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
20 (25) 20 (25) |
Compressive stress σ0 m. DBM |
MN/m² |
3,2 3,2 |
Character. Value of compressive strength fk |
MN/m² |
10,0 10,0 |
Gross density class |
2,0 2,2 |
|
Calculated weight with DBM |
kN/m³ |
20 22 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 1,70 |
Thermal resistance RT with DBM |
m²K/W |
0,55 0,49 |
U-value*) inner wall with DBM |
W/m²K |
1,83 2,05 |
U-value*) outer wall with DBM |
0,31 0,31 |
|
Sound Rw *) inner wall single shell |
dB |
62,5 61,8 |
Sound Rw **) inner wall two shells |
dB |
77 78 |
Fire resistance, α2 = 1.0, plastered |
F 90-A F 90-A |
|
Fire wall, plastered once |
yes yes |
|
Fire wall, plastered twice |
yes yes |
|
Block requirements per m² |
piece |
4 4 |
Block requirements per m3 |
piece |
16,5 16,5 |
Mortar requirements per m² |
Liter |
1,8 1,8 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,44)3 (0,44)3 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,48)3 (0,48)3 |
Packet/palette content |
piece |
16 16 |
Packet/palette content m² |
|
4 4 |
Average weight per block 1) |
kg |
119 131 |
Article number 40391070 |
39121 39206 |
|
Main field of application 2) |
6, 7 6, 7 |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 100 mm mineral fibre light-weight plaster (WLG 035)
**) plastered, onesided with 15 mm gypsum light-weight plaster, with continous 30mm parting line, filled with min. insulation
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block
3) time for m² with offset aid, as blocks are > 25 kg