KLB Flat Lintels

With prefabricated, reinforced tension belts / Approval Z-17.1-976

 

KLB flat lintels consist of a pre-fabricated, reinforced tension belt. They are only self-supporting and only reach their full load limit via a pressure zone made of masonry or concrete. The pressure zone must be made out of solid block masonry, SFK 12 (≥ 15 N/mm²) in connection with completely filled butt and horizontal joints ≥ MG II.

 

The tension belt of the KLB flat lintels consists of light-weight concrete and is reinforced with a steel rod, in contrast to the rod-reinforced or bracket-reinforced, load-bearing KLB lintels, which do not have to be enclosed in masonry and display correspondingly high load limits.

 

The support depth is respectively at least 11.5 cm. For a wall thickness ≥ 24.0 cm two or three lintels can be built-in next to each other instead of one lintel in accordance with the following sketch.

Falling variations at different wall thicknesses
  • Typ H
  • Typ A
  • Typ I
  • Typ F

KLB-flat lintels, - Typ H, b = 11,5 cm - h1 = 7,1 cm, bearing length 2 * ≥ 0,115 m

Brickwork with masonry

Articel-No

Width

Height

Length

for clear width

Centric load in kN / m

40391070

when overcast in cm

 

cm

cm

cm

cm

12,5

25,0

37,5

50,0

62,5

66110

11,5

7,1

100,0

51,0 – 76,0

2,2

7,6

12,6

12,6

12,6

66127

11,5

7,1

125,0

101,0

1,3

4,5

9,6

12,6

12,6

66134

11,5

7,1

150,0

126,0

0,9

3,0

6,4

11,0

12,6

66141

11,5

7,1

175,0

151,0

0,6

2,1

4,5

7,8

12,0

66158

11,5

7,1

200,0

176,0

0,5

1,6

3,4

5,8

9,0

 

Values ​​valid for the reinforcement 1 ∅ 8 mm

Pressure zone made of concrete

Articel-No.

Width

Height

Length

for clear width

Centric load in kN / m

40391070

when overcast in cm

 

cm

cm

cm

cm

12,5

25,0

37,5

50,0

62,5

66110

11,5

7,1

100,0

51,0 – 76,0

10,0

32,8

41,7

41,7

41,7

66127

11,5

7,1

125,0

101,0

6,7

18,7

28,1

32,3

32,3

66134

11,5

7,1

150,0

126,0

5,0

12,8

20,9

24,6

26,3

66141

11,5

7,1

175,0

151,0

4,0

9,7

17,7

17,7

21,7

66158

11,5

7,1

200,0

176,0

3,3

7,7

14,3

15,3

16,2

 

Values ​​valid for the reinforcement 1 ∅ 8 mm

                   

KLB-flat lintels, - Typ A, b = 11,5 cm - h1 = 11,5 cm, bearing length 2 * ≥ 0,115 m

Brickwork with masonry

Article No.

Width

Height

Length

for clear width

Centric load in kN / m

40391070

when overcast in cm

 

cm

cm

cm

cm

12,5

25,0

37,5

50,0

62,5

66318

11,5

11,5

100,0

51,0 – 76,0

3,8

10,3

12,6

12,6

12,6

66325

11,5

11,5

112,5

88,5

2,8

7,8

12,6

12,6

12,6

66332

11,5

11,5

125,0

101,0

2,2

6,1

11,9

12,6

12,6

66349

11,5

11,5

137,5

113,5

1,8

4,9

9,6

12,6

12,6

66356

11,5

11,5

150,0

126,0

1,5

4,0

7,9

12,6

12,6

66363

11,5

11,5

162,5

138,5

1,2

3,4

6,6

10,8

12,6

66370

11,5

11,5

175,0

151,0

1,0

2,9

5,6

9,2

12,6

66387

11,5

11,5

187,5

163,5

0,9

2,5

4,8

7,9

11,8

66394

11,5

11,5

200,0

176,0

0,8

2,1

4,2

6,9

10,2

66400

11,5

11,5

225,0

201,0

0,6

1,7

3,2

5,3

7,9

66417

11,5

11,5

250,0

226,0

0,5

1,3

2,6

4,2

6,3

66424

11,5

11,5

275,0

251,0

0,4

1,1

2,1

3,5

5,2

66431

11,5

11,5

300,0

276,0

0,4

0,9

1,7

2,9

4,3

 

Values ​​"italic" valid for the reinforcement 2 ∅ 8 mm, otherwise only 1 ∅ 8 mm

Pressure zone made of concrete

Article No.

Width

Height

Length

for clear width

Centric load in kN / m

40391070

when overcast in cm

 

cm

cm

cm

cm

12,5

25,0

37,5

50,0

62,5

66318

11,5

11,5

100,0

51,0 – 76,0

15,7

37,5

41,7

41,7

41,7

66325

11,5

11,5

112,5

88,5

12,3

28,9

36,4

36,4

36,4

66332

11,5

11,5

125,0

101,0

10,0

25,6

31,3

32,3

32,3

66349

11,5

11,5

137,5

113,5

8,5

20,3

25,2

29,0

29,0

66356

11,5

11,5

150,0

126,0

7,3

16,8

21,0

26,3

26,3

66363

11,5

11,5

162,5

138,5

6,4

14,3

19,2

22,3

24,1

66370

11,5

11,5

175,0

151,0

5,7

12,4

17,7

19,0

22,2

66387

11,5

11,5

187,5

163,5

5,1

10,9

16,4

16,5

20,0

66394

11,5

11,5

200,0

176,0

4,7

9,7

15,3

15,3

17,3

66400

11,5

11,5

225,0

201,0

4,0

8,0

13,7

22,1

26,8

66417

11,5

11,5

250,0

226,0

3,4

6,7

11,3

17,6

23,9

66424

11,5

11,5

275,0

251,0

3,0

5,8

9,6

14,6

21,4

66431

11,5

11,5

300,0

276,0

2,7

5,1

8,3

12,4

17,8

 

Values ​​"italic" valid for the reinforcement 2 ∅ 8 mm, otherwise only 1 ∅ 8 mm

KLB-flat-lintels, - Typ I, b = 17,5 cm - h1 = 7,1 cm, bearing length 2 * ≥ 0,115 m

Brickwork with masonry

Article No.

Width

Height

Length

for clear width

Centric load in kN / m

40391070

when overcast in cm

 

cm

cm

cm

cm

12,5

25,0

37,5

50,0

62,5

66219

17,5

7,1

100,0

51,0 – 76,0

3,4

11,6

19,2

19,2

19,2

66226

17,5

7,1

125,0

101,0

2,0

6,9

14,6

19,2

19,2

66233

17,5

7,1

150,0

126,0

1,3

4,6

9,7

16,8

19,2

66240

17,5

7,1

175,0

151,0

0,9

3,2

6,9

11,9

18,3

66257

17,5

7,1

200,0

176,0

0,7

2,4

5,1

8,9

13,7

 

Values ​​valid for the reinforcement 2 ∅ 8 mm

Pressure zone made of concrete

Article No.

Width

Height

Length

for clear width

Centric load in kN / m

40391070

when overcast in cm

 

cm

cm

cm

cm

12,5

25,0

37,5

50,0

62,5

66219

17,5

7,1

100,0

51,0 – 76,0

15,2

50,0

82,8

82,8

82,8

66226

17,5

7,1

125,0

101,0

10,2

28,5

55,9

64,2

64,2

66233

17,5

7,1

150,0

126,0

7,7

19,5

40,7

49,0

57,8

66240

17,5

7,1

175,0

151,0

6,1

14,7

28,5

35,3

43,3

66257

17,5

7,1

200,0

176,0

5,1

11,7

21,7

30,5

32,3

 

Values ​​valid for the reinforcement 2 ∅ 8 mm

KLB-flat-lintels, - Typ F, b = 17,5 cm - h1 = 11,5 cm, bearing length 2 * ≥ 0,115 m

Brickwork with masonry

Article No.

Width

Height

Length

for clear width

Centric load in kN / m

40391070

when overcast in cm

 

cm

cm

cm

cm

12,5

25,0

37,5

50,0

62,5

66448

17,5

11,5

100,0

51,0 – 76,0

5,7

15,6

19,2

19,2

19,2

66455

17,5

11,5

112,5

88,5

4,3

11,8

19,2

19,2

19,2

66462

17,5

11,5

125,0

101,0

3,4

9,3

18,1

19,2

19,2

66479

17,5

11,5

137,5

113,5

2,7

7,5

14,5

19,2

19,2

66486

17,5

11,5

150,0

126,0

2,2

6,1

12,0

19,2

19,2

66493

17,5

11,5

162,5

138,5

1,9

5,1

10,0

16,5

(19,2)

66509

17,5

11,5

175,0

151,0

1,6

4,4

8,5

14,0

(18,5)

66516

17,5

11,5

187,5

163,5

1,4

3,7

7,3

12,0

(16,6)

66523

17,5

11,5

200,0

176,0

1,2

3,3

6,3

10,4

(14,4)

66530

17,5

11,5

225,0

201,0

0,9

2,5

4,9

8,1

12,0

66547

17,5

11,5

250,0

226,0

0,7

2,0

3,9

6,4

9,6

66554

17,5

11,5

275,0

251,0

0,6

1,6

3,2

5,3

7,8

66561

17,5

11,5

300,0

276,0

0,5

1,4

2,7

4,4

6,5

 

Values ​​"italic" valid for the reinforcement 2 ∅ 10 mm, otherwise only 2 ∅ 8 mm

 

() Values: the degree of reinforcement according to para. 3.3.3 (1) is below 0.05%

Pressure zone made of concrete

Article No.

Width

Height

Length

for clear width

Centric load in kN / m

40391070

when overcast in cm

 

cm

cm

cm

cm

12,5

25,0

37,5

50,0

62,5

66448

17,5

11,5

100,0

51,0 – 76,0

23,9

74,2

82,8

82,8

82,8

66455

17,5

11,5

112,5

88,5

18,7

51,4

72,4

72,4

72,4

66462

17,5

11,5

125,0

101,0

15,3

38,8

62,3

64,2

64,2

66479

17,5

11,5

137,5

113,5

12,9

30,9

50,2

57,8

57,8

66486

17,5

11,5

150,0

126,0

11,1

25,6

41,8

52,5

52,5

66493

17,5

11,5

162,5

138,5

9,8

21,7

38,2

44,5

48,2

66509

17,5

11,5

175,0

151,0

8,7

18,8

35,2

37,8

44,3

66516

17,5

11,5

187,5

163,5

7,8

16,6

30,2

32,8

39,8

66523

17,5

11,5

200,0

176,0

7,1

14,8

26,4

30,6

34,6

66530

17,5

11,5

225,0

201,0

6,0

21,1

20,8

33,4

33,6

66547

17,5

11,5

250,0

226,0

5,2

10,2

17,1

26,7

30,0

66554

17,5

11,5

275,0

251,0

4,6

8,8

14,5

22,2

27,1

66561

17,5

11,5

300,0

276,0

4,1

7,8

12,6

18,9

24,7

 