Flat full blocks and KLB flat sound insulation blocks
Small-sized, solid supplementary blocks, suitable for sound-insulating masonry
KLB flat full blocks are small-sized, solid supplementary blocks, which are thermally adapted to the KLB flat blocks. The blocks have a height of 124 mm and a length of 249 mm. The fronts are, in contrast to the KLB flat blocks with their dovetailing in the butt joint, smooth and therefore have to be processed in the horizontal joint and butt joint with thin-bed mortar.
The 8 DF flat solid blocks alone (flat building panels height 249 mm, length 497 mm, thickness 115 mm) have simple dovetailing, with the groove on one side and the tongue on the other side but they do not have to be mortared. The flat solid blocks are used for any partitions in the KLB flat block masonry. Due to the different formats all masonry thicknesses can be supplemented. The calculated values of the heat conductivity numbers correspond to the compliance certificate ÜZ WBK1-2005/0510.
KLB flat sound insulation blocks correspond in their dimensions to the KLB flat solid stones. The processing also includes mortaring the load-bearing joints and butt joints with thin-bed mortar. In particular, these solid blocks are used for any partitions or additions in the sound-insulating masonry.
- 11,5 cm
- 17,5 cm
- 24,0 cm
- 30,0 cm
- 36,5 cm
Type of block |
KLB-Flat full blocks Z-17.1-778 |
||
---|---|---|---|
Wall thickness |
cm |
11,5 |
|
Format |
2 DF |
8 DF N+F |
|
Length |
mm |
249 |
497 |
Width |
mm |
115 |
115 |
Height |
mm |
124 |
249 |
Number of chamber/slot rows |
- |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) 4(5,0) |
2 (2,5) 4 (5,0) 2 (2,5) |
Compressive stress σ0 m. DBM |
MN/m² |
0,6 0,9 |
0,6 0,9 0,6 |
Character. Value of compressive strength fk |
MN/m² |
1,5 2,8 |
1,5 2,8 1,5 |
Gross density class |
0,60 0,80 |
0,60 0,80 1,0 |
|
Calculated weight with DBM |
kN/m³ |
7 9 |
7 9 11 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,15 0,21 |
0,15 0,21 0,27 |
Thermal resistance RT with DBM |
m²K/W |
1,11 0,89 |
1,11 0,89 0,77 |
U-value*) inner wall with DBM |
W/m²K |
0,90 1,12 |
0,90 1,12 0,77 |
U-value*) outer wall with DBM |
- - |
- - - |
|
Sound Rw *) inner wall single shell |
dB |
37,6 40,4 |
37,6 40,4 43,0 |
Sound Rw **) inner wall two shells |
dB |
- - |
- - - |
Fire resistance, α2 = 1.0, plastered |
F180-A |
F180-A |
|
Fire wall, plastered once |
no |
no |
|
Fire wall, plastered twice |
no |
no |
|
Block requirements per m² |
piece |
32 32 |
8 8 8 |
Block requirements per m³ |
piece |
278 278 |
- - - |
Mortar requirements per m² |
Liter |
- - |
2,0 2,0 2,0 |
Mortar requirements per m³ |
Liter |
36 36 |
- - - |
Working time reference value full masonry |
h/m³(h/m²) |
(0,60) (0,70) |
(0,40) (0,40) (0,44) |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,60) (0,70) |
(0,45) (0,45) (0,49) |
Packet/palette content |
piece |
320 320 |
80 80 80 |
Average weight per block 1) |
kg |
2,6 3,2 |
10,1 12,9 16,1 |
Article number 40391070 |
37349 35628 |
37363 35314 36618 |
|
Main field of application 2) |
5, x 5, x |
5, x 5, x 5, x |
Type of block |
KLB-Flat full blocks Z-17.1-778 |
|
---|---|---|
Wall thickness |
cm |
17,5 |
Format |
3 DF |
|
Length |
mm |
249 |
Width |
mm |
175 |
Height |
mm |
124 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) 4(5,0) |
Compressive stress σ0 m. DBM |
MN/m² |
0,6 0,9 |
Character. Value of compressive strength fk |
MN/m² |
1,5 2,8 |
Gross density class |
0,60 0,80 |
|
Calculated weight with DBM |
kN/m³ |
7 9 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,15 0,21 |
Thermal resistance RT with DBM |
m²K/W |
1,51 1,18 |
U-value*) inner wall with DBM |
W/m²K |
0,65 0,85 |
U-value*) outer wall with DBM |
0,24 0,26 |
|
Sound Rw *) inner wall single shell |
dB |
42,1 47,2 |
Sound Rw **) inner wall two shells |
dB |
62 65 |
Fire resistance, α2 = 1.0, plastered |
F120-A |
|
Fire wall, plastered once |
no yes |
|
Fire wall, plastered twice |
yes |
|
Block requirements per m² |
piece |
32 32 |
Block requirements per m³ |
piece |
183 183 |
Mortar requirements per m² |
Liter |
- - |
Mortar requirements per m³ |
Liter |
36 36 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,40) (0,42) |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,45) (0,47) |
Packet/palette content |
piece |
200/224 200/224 |
Average weight per block 1) |
kg |
3,9 5,0 |
Article number 40391070 |
37387 35666 |
|
Main field of application 2) |
5, x 5, x |
Type of block |
KLB-Flat full blocks Z-17.1-778 |
|
---|---|---|
Wall thickness |
cm |
24,0 |
Format |
6 DF |
|
Length |
mm |
365 |
Width |
mm |
240 |
Height |
mm |
124 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) 4(5,0) |
Compressive stress σ0 m. DBM |
MN/m² |
0,6 0,9 |
Character. Value of compressive strength fk |
MN/m² |
1,5 2,8 |
Gross density class |
0,60 0,80 |
|
Calculated weight with DBM |
kN/m³ |
7 9 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,15 0,21 |
Thermal resistance RT with DBM |
m²K/W |
1,95 1,49 |
U-value*) inner wall with DBM |
W/m²K |
0,61 0,67 |
U-value*) outer wall with DBM |
0,21 0,24 |
|
Sound Rw *) inner wall single shell |
dB |
47,7 50,9 |
Sound Rw **) inner wall two shells |
dB |
66 69 |
Fire resistance, α2 = 1.0, plastered |
F180-A |
|
Fire wall, plastered once |
yes |
|
Fire wall, plastered twice |
yes |
|
Block requirements per m² |
piece |
22 22 |
Block requirements per m³ |
piece |
91 91 |
Mortar requirements per m² |
Liter |
- - |
Mortar requirements per m³ |
Liter |
33 33 |
Working time reference value full masonry |
h/m³(h/m²) |
(3,35) (3,40) |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(3,70) (3,75) |
Packet/palette content |
piece |
105 105 |
Average weight per block 1) |
kg |
7,8 10,0 |
Article number 40391070 |
37417 35765 |
|
Main field of application 2) |
5, x 5, x |
Type of block |
KLB-Flat full blocks Z-17.1-778 |
|
---|---|---|
Wall thickness |
cm |
30 |
Format |
5 DF |
|
Length |
mm |
249 |
Width |
mm |
300 |
Height |
mm |
124 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) 4(5,0) |
Compressive stress σ0 m. DBM |
MN/m² |
0,6 0,9 |
Character. Value of compressive strength fk |
MN/m² |
1,5 2,8 |
Gross density class |
0,60 0,80 |
|
Calculated weight with DBM |
kN/m³ |
7 9 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,15 0,21 |
Thermal resistance RT with DBM |
m²K/W |
2,35 1,77 |
U-value*) inner wall with DBM |
W/m²K |
0,43 0,56 |
U-value*) outer wall with DBM |
0,2 0,22 |
|
Sound Rw *) inner wall single shell |
dB |
50,4 53,6 |
Sound Rw **) inner wall two shells |
dB |
- - |
Fire resistance, α2 = 1.0, plastered |
F180-A |
|
Fire wall, plastered once |
yes |
|
Fire wall, plastered twice |
yes |
|
Block requirements per m² |
piece |
32 32 |
Block requirements per m³ |
piece |
107 107 |
Mortar requirements per m² |
Liter |
- - |
Mortar requirements per m³ |
Liter |
36 36 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,70) (0,80) |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,70) (0,80) |
Packet/palette content |
piece |
120 120 |
Average weight per block 1) |
kg |
6,6 8,5 |
Article number 40391070 |
37448 35710 |
|
Main field of application 2) |
5, x 5, x |
Type of block |
KLB-Flat full blocks Z-17.1-778 |
|
---|---|---|
Wall thickness |
cm |
36,5 |
Format |
6 DF |
|
Length |
mm |
249 |
Width |
mm |
365 |
Height |
mm |
124 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) 4(5,0) |
Compressive stress σ0 m. DBM |
MN/m² |
0,6 0,9 |
Character. Value of compressive strength fk |
MN/m² |
1,5 2,8 |
Gross density class |
0,60 0,80 |
|
Calculated weight with DBM |
kN/m³ |
7 9 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,15 0,21 |
Thermal resistance RT with DBM |
m²K/W |
2,78 2,08 |
U-value*) inner wall with DBM |
W/m²K |
0,36 0,48 |
U-value*) outer wall with DBM |
0,18 0,21 |
|
Sound Rw *) inner wall single shell |
dB |
52,8 56,1 |
Sound Rw **) inner wall two shells |
dB |
- - |
Fire resistance, α2 = 1.0, plastered |
F180-A |
|
Fire wall, plastered once |
yes |
|
Fire wall, plastered twice |
yes |
|
Block requirements per m² |
piece |
32 32 |
Block requirements per m³ |
piece |
105 105 |
Mortar requirements per m² |
Liter |
- - |
Mortar requirements per m³ |
Liter |
36 36 |
Working time reference value full masonry |
h/m³(h/m²) |
(2,90) (3,20) |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(2,95) (3,25) |
Packet/palette content |
piece |
105 105 |
Average weight per block 1) |
kg |
8,0 10,3 |
Article number 40391070 |
37479 35819 |
|
Main field of application 2) |
5, x 5, x |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 20 mm mineral fibre light-weight plaster λR = 0.31 W/mK
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block
- 11,5 cm
- 17,5 cm
- 24,0 cm
- 30,0 cm
- 36,5 cm
Type of block |
KLB flat sound insulation blocks - Z-17.1-778 |
||
---|---|---|---|
Wall thickness |
cm |
11,5 |
|
Format |
2 DF |
8 DF N+F |
|
Length |
mm |
249 |
497 |
Width |
mm |
115 |
115 |
Height |
mm |
124 |
249 |
Number of chamber/slot rows |
- |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
20 (25) |
12 (15) |
Compressive stress σ0 m. DBM |
MN/m² |
3,2 |
2,2 |
Character. Value of compressive strength fk |
MN/m² |
10,0 |
6,9 |
Gross density class |
2,0 |
2,0 |
|
Calculated weight with DBM |
kN/m³ |
20 |
20 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 |
1,20 |
Thermal resistance RT with DBM |
m²K/W |
0,44 |
0,44 |
U-value*) inner wall with DBM |
W/m²K |
2,26 |
2,26 |
U-value*) outer wall with DBM |
- |
- |
|
Sound Rw *) inner wall single shell |
dB |
53,3 |
53,3 |
Sound Rw **) inner wall two shells |
dB |
71 |
71 |
Fire resistance, α2 = 1.0, plastered |
- |
- |
|
Fire wall, plastered once |
no |
no |
|
Fire wall, plastered twice |
no |
no |
|
Block requirements per m² |
piece |
32 |
8 |
Block requirements per m³ |
piece |
278 |
46 |
Mortar requirements per m² |
Liter |
5,2 |
2,6 |
Mortar requirements per m³ |
Liter |
36 |
30 |
Working time reference value full masonry |
h/m³(h/m²) |
3,45 |
3,45 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
3,80 |
3,80 |
Packet/palette content |
piece |
256 |
64 |
Average weight per block 1) |
kg |
6,9 |
28,3 |
Article number 40391070 |
37356 |
37370 |
|
Main field of application 2) |
4, x |
4, x |
Type of block |
KLB flat sound insulation blocks - Z-17.1-778 |
|
---|---|---|
Wall thickness |
cm |
17,5 |
Format |
3 DF |
|
Length |
mm |
249 |
Width |
mm |
175 |
Height |
mm |
124 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
20 (15) |
Compressive stress σ0 m. DBM |
MN/m² |
2,2 |
Character. Value of compressive strength fk |
MN/m² |
6,9 |
Gross density class |
2,0 |
|
Calculated weight with DBM |
kN/m³ |
20 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 |
Thermal resistance RT with DBM |
m²K/W |
0,49 |
U-value*) inner wall with DBM |
W/m²K |
2,03 |
U-value*) outer wall with DBM |
0,31 |
|
Sound Rw *) inner wall single shell |
dB |
58,5 |
Sound Rw **) inner wall two shells |
dB |
74 |
Fire resistance, α2 = 1.0, plastered |
F 120-A |
|
Fire wall, plastered once |
yes |
|
Fire wall, plastered twice |
yes |
|
Block requirements per m² |
piece |
32 |
Block requirements per m³ |
piece |
183 |
Mortar requirements per m² |
Liter |
7,9 |
Mortar requirements per m³ |
Liter |
36 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,60) |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,70) |
Packet/palette content |
piece |
160 |
Average weight per block 1) |
kg |
10,7 |
Article number 40391070 |
37400 |
|
Main field of application 2) |
4, x |
Type of block |
KLB flat sound insulation blocks - Z-17.1-778 |
|
---|---|---|
Wall thickness |
cm |
24,0 |
Format |
6 DF |
|
Length |
mm |
365 |
Width |
mm |
240 |
Height |
mm |
124 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
20 (15) |
Compressive stress σ0 m. DBM |
MN/m² |
2,2 |
Character. Value of compressive strength fk |
MN/m² |
6,9 |
Gross density class |
2,0 |
|
Calculated weight with DBM |
kN/m³ |
20 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 |
Thermal resistance RT with DBM |
m²K/W |
0,55 |
U-value*) inner wall with DBM |
W/m²K |
1,83 |
U-value*) outer wall with DBM |
0,28 |
|
Sound Rw *) inner wall single shell |
dB |
62,5 |
Sound Rw **) inner wall two shells |
dB |
77 |
Fire resistance, α2 = 1.0, plastered |
F 180-A |
|
Fire wall, plastered once |
yes |
|
Fire wall, plastered twice |
yes |
|
Block requirements per m² |
piece |
22 |
Block requirements per m³ |
piece |
91 |
Mortar requirements per m² |
Liter |
9,9 |
Mortar requirements per m³ |
Liter |
33 |
Working time reference value full masonry |
h/m³(h/m²) |
3,60 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
3,95 |
Packet/palette content |
piece |
84 |
Average weight per block 1) |
kg |
21,5 |
Article number 40391070 |
37561 |
|
Main field of application 2) |
4, x |
Type of block |
KLB flat sound insulation blocks - Z-17.1-778 |
|
---|---|---|
Wall thickness |
cm |
30,0 |
Format |
5 DF |
|
Length |
mm |
249 |
Width |
mm |
300 |
Height |
mm |
124 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
12 (15) |
Compressive stress σ0 m. DBM |
MN/m² |
2,2 |
Character. Value of compressive strength fk |
MN/m² |
6,9 |
Gross density class |
2,0 |
|
Calculated weight with DBM |
kN/m³ |
20 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 |
Thermal resistance RT with DBM |
m²K/W |
0,60 |
U-value*) inner wall with DBM |
W/m²K |
1,68 |
U-value*) outer wall with DBM |
0,30 |
|
Sound Rw *) inner wall single shell |
dB |
63,4 |
Sound Rw **) inner wall two shells |
dB |
- |
Fire resistance, α2 = 1.0, plastered |
F 180-A |
|
Fire wall, plastered once |
yes |
|
Fire wall, plastered twice |
yes |
|
Block requirements per m² |
piece |
32 |
Block requirements per m³ |
piece |
107 |
Mortar requirements per m² |
Liter |
13,5 |
Mortar requirements per m³ |
Liter |
36 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,70) |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,80) |
Packet/palette content |
piece |
96 |
Average weight per block 1) |
kg |
11,0 |
Article number 40391070 |
37462 |
|
Main field of application 2) |
4, x |
Type of block |
KLB flat sound insulation blocks - Z-17.1-778 |
|
---|---|---|
Wall thickness |
cm |
36,5 |
Format |
6 DF |
|
Length |
mm |
249 |
Width |
mm |
365 |
Height |
mm |
124 |
Number of chamber/slot rows |
- |
|
Tensile strength class (medium tensile strength) |
(N/mm²) |
12 (15) |
Compressive stress σ0 m. DBM |
MN/m² |
2,2 |
Character. Value of compressive strength fk |
MN/m² |
6,9 |
Gross density class |
2,0 |
|
Calculated weight with DBM |
kN/m³ |
20 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
1,20 |
Thermal resistance RT with DBM |
m²K/W |
0,65 |
U-value*) inner wall with DBM |
W/m²K |
1,54 |
U-value*) outer wall with DBM |
0,30 |
|
Sound Rw *) inner wall single shell |
dB |
66 |
Sound Rw **) inner wall two shells |
dB |
- |
Fire resistance, α2 = 1.0, plastered |
F 180-A |
|
Fire wall, plastered once |
yes |
|
Fire wall, plastered twice |
yes |
|
Block requirements per m² |
piece |
32 |
Block requirements per m³ |
piece |
88 |
Mortar requirements per m² |
Liter |
16,4 |
Mortar requirements per m³ |
Liter |
36 |
Working time reference value full masonry |
h/m³(h/m²) |
3,25 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
3,55 |
Packet/palette content |
piece |
84 |
Average weight per block 1) |
kg |
22,4 |
Article number 40391070 |
37493 |
|
Main field of application 2) |
4, x |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 20 mm mineral fibre light-weight plaster λR = 0.31 W/mK
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block
3) time for m² with offset aid, as blocks are > 25 kg