KLB height offset blocks, thermally insulated

KLB height offset blocks, thermally insulated

 

To achieve space heights that deviate from the 25 cm grid, KLB offers thermally insulating, slotted vbl height offset blocks of type SW1 with a height adapted to the flat solid blocks of 124 mm. The length of these blocks corresponds to the standard height blocks with 30 cm thickness = 497 mm, with 36.5 cm thickness = 247 mm. The blocks are manufactured in the strength classes 2 and 4 with the gross density classes 0.45 and 0.60. The coefficient of thermal conductivity matches the SW1 flat blocks with thermal conductivities λR = 0.10 W/mK or λR = 0.14 W/mK respectively.

 

These blocks form the upper wall finish for the thermal insulating blocks SW1 or W3 finished with thin-bed or thick-bed joint.

  • 30 cm
  • 36,5 cm
  • 42,5 cm
  • 49 cm

Type of block

KLB height offset blocks SW1 -Z17.1-730

Wall thickness

cm

30

Format

 

10 DF

Length

mm

497

Width

mm

300

Height

mm

124

Number of chamber/slot rows

  -

Tensile strength class (medium tensile strength)

(N/mm²)

2 (2,5)

Compressive stress σ0 m. DBM "L"

MN/m²

0,5

Character. Value of compressive strength fk

MN/m²

1,5

Gross density class

 

0,45

Calculated weight with DBM

kN/m³

5,5

Coefficient of thermal conductivity λR with DBM "L"

W/mK

0,10

Thermal resistance  RT with DBM

m²K/W

3,28

U-value*) with DBM

W/m²K

0,30

Heat storage capacity

kJ/m²K

203

Cool down time

h

175

Fire resistance, α2

 

F 30-A

   

Fire wall, plastered once

 

no

Block requirements per lfdm

piece

2

Mortar requirements per lfdm

Liter

0,6

Working time reference value full masonry

h/m³(h/m²)

(0,80)

Working time reference value categorised. Masonry

h/m³(h/m²)

(1,00)

Packet/palette content

piece

80

Average weight per block 1)

kg

11,0

Article number 40391070

 

36472

Main field of application 2)

 

2,3

Type of block

KLB height offset blocks SW1 -Z17.1-730

Wall thickness

cm

36,5

Format

 

6 DF

Length

mm

247

Width

mm

365

Height

mm

124

Number of chamber/slot rows

  -

Tensile strength class (medium tensile strength)

(N/mm²)

2 (2,5)             4(5,0)

Compressive stress σ0 m. DBM "L"

MN/m²

0,5            0,9

Character. Value of compressive strength fk

MN/m²

1,5       2,7

Gross density class

 

0,45       0,6

Calculated weight with DBM

kN/m³

5,5       7,0

Coefficient of thermal conductivity λR with DBM "L"

W/mK

0,10       0,14

Thermal resistance  RT with DBM

m²K/W

3,93       2,89

U-value*) with DBM

W/m²K

0,25       0,35

Heat storage capacity

kJ/m²K

239       288

Cool down time

h

249       218

Fire resistance, α2

 

F 90-A       F 90-A

   

Fire wall, plastered once

 

no       no

Block requirements per lfdm

piece

4       4

Mortar requirements per lfdm

Liter

0,8       0,8

Working time reference value full masonry

h/m³(h/m²)

(0,90)       (1,00)

Working time reference value categorised. Masonry

h/m³(h/m²)

(1,10)       (1,20)

Packet/palette content

piece

120       120

Average weight per block 1)

kg

6,5       8,5

Article number 40391070

 

36496       36564

Main field of application 2)

 

2,3       2,3

Type of block

KLB height offset blocks SW1 -Z17.1-730

Wall thickness

cm

42,5

Format

 

7 DF

Length

mm

247

Width

mm

425

Height

mm

124

Number of chamber/slot rows

  -

Tensile strength class (medium tensile strength)

(N/mm²)

2 (2,5)

Compressive stress σ0 m. DBM "L"

MN/m²

0,5

Character. Value of compressive strength fk

MN/m²

1,5

Gross density class

 

0,45

Calculated weight with DBM

kN/m³

5,5

Coefficient of thermal conductivity λR with DBM "L"

W/mK

0,10

Thermal resistance  RT with DBM

m²K/W

4,53

U-value*) with DBM

W/m²K

0,22

Heat storage capacity

kJ/m²K

229

Cool down time

h

275

Fire resistance, α2

 

F 90-A

   

Fire wall, plastered once

 

no

Block requirements per lfdm

piece

4

Mortar requirements per lfdm

Liter

1,0

Working time reference value full masonry

h/m³(h/m²)

(1,00)

Working time reference value categorised. Masonry

h/m³(h/m²)

(1,20)

Packet/palette content

piece

80

Average weight per block 1)

kg

7,5

Article number 40391070

 

36977

Main field of application 2)

 

2,3

Type of block

KLB height offset blocks SW1 -Z17.1-730

Wall thickness

cm

49,0

Format

 

8 DF

Length

mm

247

Width

mm

490

Height

mm

124

Number of chamber/slot rows

  -

Tensile strength class (medium tensile strength)

(N/mm²)

2 (2,5)

Compressive stress σ0 m. DBM "L"

MN/m²

0,5

Character. Value of compressive strength fk

MN/m²

1,5

Gross density class

 

0,45

Calculated weight with DBM

kN/m³

5,5

Coefficient of thermal conductivity λR with DBM "L"

W/mK

0,10

Thermal resistance  RT with DBM

m²K/W

5,18

U-value*) with DBM

W/m²K

0,19

Heat storage capacity

kJ/m²K

259

Cool down time

h

375

Fire resistance, α2

 

F 90-A

   

Fire wall, plastered once

 

no

Block requirements per lfdm

piece

4

Mortar requirements per lfdm

Liter

1,2

Working time reference value full masonry

h/m³(h/m²)

(1,05)

Working time reference value categorised. Masonry

h/m³(h/m²)

(1,25)

Packet/palette content

piece

80

Average weight per block 1)

kg

8,5

Article number 40391070

 

37332

Main field of application 2)

 

2,3