KLB height offset blocks, thermally insulated
KLB height offset blocks, thermally insulated
To achieve space heights that deviate from the 25 cm grid, KLB offers thermally insulating, slotted vbl height offset blocks of type SW1 with a height adapted to the flat solid blocks of 124 mm. The length of these blocks corresponds to the standard height blocks with 30 cm thickness = 497 mm, with 36.5 cm thickness = 247 mm. The blocks are manufactured in the strength classes 2 and 4 with the gross density classes 0.45 and 0.60. The coefficient of thermal conductivity matches the SW1 flat blocks with thermal conductivities λR = 0.10 W/mK or λR = 0.14 W/mK respectively.
These blocks form the upper wall finish for the thermal insulating blocks SW1 or W3 finished with thin-bed or thick-bed joint.
- 30 cm
- 36,5 cm
- 42,5 cm
- 49 cm
Type of block |
KLB height offset blocks SW1 -Z17.1-730 |
|||
---|---|---|---|---|
Wall thickness |
cm |
30 |
||
Format |
10 DF |
|||
Length |
mm |
497 |
||
Width |
mm |
300 |
||
Height |
mm |
124 |
||
Number of chamber/slot rows |
- | |||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
||
Compressive stress σ0 m. DBM "L" |
MN/m² |
0,5 |
||
Character. Value of compressive strength fk |
MN/m² |
1,5 |
||
Gross density class |
0,45 |
|||
Calculated weight with DBM |
kN/m³ |
5,5 |
||
Coefficient of thermal conductivity λR with DBM "L" |
W/mK |
0,10 |
||
Thermal resistance RT with DBM |
m²K/W |
3,28 |
||
U-value*) with DBM |
W/m²K |
0,30 |
||
Heat storage capacity |
kJ/m²K |
203 |
||
Cool down time |
h |
175 |
||
Fire resistance, α2 |
F 30-A |
|||
Fire wall, plastered once |
no |
|||
Block requirements per lfdm |
piece |
2 |
||
Mortar requirements per lfdm |
Liter |
0,6 |
||
Working time reference value full masonry |
h/m³(h/m²) |
(0,80) |
||
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(1,00) |
||
Packet/palette content |
piece |
80 |
||
Average weight per block 1) |
kg |
11,0 |
||
Article number 40391070 |
36472 |
|||
Main field of application 2) |
2,3 |
Type of block |
KLB height offset blocks SW1 -Z17.1-730 |
|||
---|---|---|---|---|
Wall thickness |
cm |
36,5 |
||
Format |
6 DF |
|||
Length |
mm |
247 |
||
Width |
mm |
365 |
||
Height |
mm |
124 |
||
Number of chamber/slot rows |
- | |||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) 4(5,0) |
||
Compressive stress σ0 m. DBM "L" |
MN/m² |
0,5 0,9 |
||
Character. Value of compressive strength fk |
MN/m² |
1,5 2,7 |
||
Gross density class |
0,45 0,6 |
|||
Calculated weight with DBM |
kN/m³ |
5,5 7,0 |
||
Coefficient of thermal conductivity λR with DBM "L" |
W/mK |
0,10 0,14 |
||
Thermal resistance RT with DBM |
m²K/W |
3,93 2,89 |
||
U-value*) with DBM |
W/m²K |
0,25 0,35 |
||
Heat storage capacity |
kJ/m²K |
239 288 |
||
Cool down time |
h |
249 218 |
||
Fire resistance, α2 |
F 90-A F 90-A |
|||
Fire wall, plastered once |
no no |
|||
Block requirements per lfdm |
piece |
4 4 |
||
Mortar requirements per lfdm |
Liter |
0,8 0,8 |
||
Working time reference value full masonry |
h/m³(h/m²) |
(0,90) (1,00) |
||
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(1,10) (1,20) |
||
Packet/palette content |
piece |
120 120 |
||
Average weight per block 1) |
kg |
6,5 8,5 |
||
Article number 40391070 |
36496 36564 |
|||
Main field of application 2) |
2,3 2,3 |
Type of block |
KLB height offset blocks SW1 -Z17.1-730 |
|||
---|---|---|---|---|
Wall thickness |
cm |
42,5 |
||
Format |
7 DF |
|||
Length |
mm |
247 |
||
Width |
mm |
425 |
||
Height |
mm |
124 |
||
Number of chamber/slot rows |
- | |||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
||
Compressive stress σ0 m. DBM "L" |
MN/m² |
0,5 |
||
Character. Value of compressive strength fk |
MN/m² |
1,5 |
||
Gross density class |
0,45 |
|||
Calculated weight with DBM |
kN/m³ |
5,5 |
||
Coefficient of thermal conductivity λR with DBM "L" |
W/mK |
0,10 |
||
Thermal resistance RT with DBM |
m²K/W |
4,53 |
||
U-value*) with DBM |
W/m²K |
0,22 |
||
Heat storage capacity |
kJ/m²K |
229 |
||
Cool down time |
h |
275 |
||
Fire resistance, α2 |
F 90-A |
|||
Fire wall, plastered once |
no |
|||
Block requirements per lfdm |
piece |
4 |
||
Mortar requirements per lfdm |
Liter |
1,0 |
||
Working time reference value full masonry |
h/m³(h/m²) |
(1,00) |
||
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(1,20) |
||
Packet/palette content |
piece |
80 |
||
Average weight per block 1) |
kg |
7,5 |
||
Article number 40391070 |
36977 |
|||
Main field of application 2) |
2,3 |
Type of block |
KLB height offset blocks SW1 -Z17.1-730 |
|||
---|---|---|---|---|
Wall thickness |
cm |
49,0 |
||
Format |
8 DF |
|||
Length |
mm |
247 |
||
Width |
mm |
490 |
||
Height |
mm |
124 |
||
Number of chamber/slot rows |
- | |||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
||
Compressive stress σ0 m. DBM "L" |
MN/m² |
0,5 |
||
Character. Value of compressive strength fk |
MN/m² |
1,5 |
||
Gross density class |
0,45 |
|||
Calculated weight with DBM |
kN/m³ |
5,5 |
||
Coefficient of thermal conductivity λR with DBM "L" |
W/mK |
0,10 |
||
Thermal resistance RT with DBM |
m²K/W |
5,18 |
||
U-value*) with DBM |
W/m²K |
0,19 |
||
Heat storage capacity |
kJ/m²K |
259 |
||
Cool down time |
h |
375 |
||
Fire resistance, α2 |
F 90-A |
|||
Fire wall, plastered once |
no |
|||
Block requirements per lfdm |
piece |
4 |
||
Mortar requirements per lfdm |
Liter |
1,2 |
||
Working time reference value full masonry |
h/m³(h/m²) |
(1,05) |
||
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(1,25) |
||
Packet/palette content |
piece |
80 |
||
Average weight per block 1) |
kg |
8,5 |
||
Article number 40391070 |
37332 |
|||
Main field of application 2) |
2,3 |