Flat hollow blocks
Blocks for additionally insulated, load-bearing basement, exterior and interior walls / Approval Z-17.1-797
KLB flat hollow blocks are the reasonable complements to the highly thermally insulating KLB flat blocks SW1 and W3. They are used as additionally insulated back wall shell or as load-bearing basement, exterior or interior walls, in particular for components which have no significant requirements regarding heat and/or sound.
KLB flat hollow blocks are manufactured in accordance with DIN V 18151-100 and are approved by the building authority, Approval Z-17.1-842 und Z-17.1-844
- 17,5 cm
- 24,0 cm
- 30,0 cm
- 36,5 cm
Type of block |
KLB flat hollow blocks - Z-17.1-797 |
|||
---|---|---|---|---|
Wall thickness |
cm |
17,5 |
||
Format |
12 DF |
|||
Length |
mm |
497 |
||
Width |
mm |
175 |
||
Height |
mm |
249 |
||
Number of chamber/slot rows |
1 |
|||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
4 (5,0) |
6 (7,5) |
Compressive stress σ0 m. DBM |
MN/m² |
0,5 |
0,8 |
1,0 |
Character. Value of compressive strength fk |
MN/m² |
1,6 |
2,5 |
3,2 |
Gross density class |
0,8 |
0,9 |
1,2 |
|
Calculated weight with DBM |
kN/m³ |
9,0 |
10,0 |
13,0 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,34 |
0,37 |
0,60 |
Thermal resistance RT with DBM |
m²K/W |
3,59 |
3,54 |
3,36 |
U-value*) with DBM |
W/m²K |
0,28 |
0,28 |
0,30 |
Heat storage capacity |
F 120-A |
|||
Fire wall, plastered once |
no |
|||
Fire wall, plastered twice **) |
no |
|||
Block requirements per m² |
piece |
8 |
8 |
8 |
Block requirements per m³ |
piece |
46 |
46 |
46 |
Mortar requirements per m² |
Liter |
2,6 |
2,6 |
2,6 |
Mortar requirements per m³ |
Liter |
12 |
12 |
12 |
Working time reference value full masonry |
h/m³(h/m²) |
(0,42) |
(0,42) |
(0,45) |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
(0,47) |
(0,47) |
(0,50) |
Packet/palette content |
piece |
50/60 |
50/60 |
50/60 |
Average weight per block 1) |
kg |
20 |
22 |
26 |
Article number 40391070 |
34508 |
34515 |
34522 |
|
Main field of application 2) |
3, 4 |
3, 4 |
3, 4 |
Type of block |
KLB flat hollow blocks - Z-17.1-797 |
|||||
---|---|---|---|---|---|---|
Wall thickness |
cm |
24,0 |
||||
Format |
16 DF |
8 DF |
||||
Length |
mm |
497 |
247 |
|||
Width |
mm |
240 |
240 |
|||
Height |
mm |
249 |
249 |
|||
Number of chamber/slot rows |
3 |
2 |
||||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
4 (5,0) |
2 (2,5) |
4 (5,0) |
6 (7,5) |
Compressive stress σ0 m. DBM |
MN/m² |
0,5 |
0,8 |
0,5 |
0,8 |
1,0 |
Character. Value of compressive strength fk |
MN/m² |
1,6 |
2,5 |
1,6 |
2,5 |
3,2 |
Gross density class |
0,8 |
0,9 |
0,8 |
0,9 |
1,2 |
|
Calculated weight with DBM |
kN/m³ |
9,0 |
10,0 |
9,0 |
10,0 |
13,0 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,31 |
0,34 |
0,31 |
0,34 |
0,53 |
Thermal resistance RT with DBM |
m²K/W |
3,84 |
3,78 |
3,84 |
3,78 |
3,52 |
U-value*) with DBM |
W/m²K |
0,26 |
0,26 |
0,26 |
0,26 |
0,28 |
Heat storage capacity |
F 180-A |
F 180-A | ||||
Fire wall, plastered once |
yes |
yes |
||||
Fire wall, plastered twice **) |
yes |
yes |
||||
Block requirements per m² |
piece |
8 |
8 |
16 |
16 |
16 |
Block requirements per m³ |
piece |
33 |
33 |
66 |
66 |
66 |
Mortar requirements per m² |
Liter |
3,0 |
3,0 |
3,0 |
3,0 |
3,0 |
Mortar requirements per m³ |
Liter |
12 |
12 |
12 |
12 |
12 |
Working time reference value full masonry |
h/m³(h/m²) |
2,00 |
2,15 |
2,00 |
2,05 |
2,20 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
2,20 |
2,35 |
2,20 |
2,25 |
2,40 |
Packet/palette content |
piece |
40 |
40 |
80 |
80 |
80 |
Average weight per block 1) |
kg |
27 |
31 |
14 |
15 |
18 |
Article number 40391070 |
34539 |
34546 |
36052 |
36212 |
36359 |
|
Main field of application 2) |
3, 4 |
3, 4 |
3, 4 |
3, 4 |
3, 4 |
Type of block |
KLB flat hollow blocks - Z-17.1-797 |
||||
---|---|---|---|---|---|
Wall thickness |
cm |
30,0 |
|||
Format |
20 DF |
10 DF |
|||
Length |
mm |
497 |
247 |
||
Width |
mm |
300 |
300 |
||
Height |
mm |
249 |
249 |
||
Number of chamber/slot rows |
3 |
3 |
|||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
2 (2,5) |
4 (5,0) |
6 (7,5) |
Compressive stress σ0 m. DBM |
MN/m² |
0,5 |
0,5 |
0,8 |
1,0 |
Character. Value of compressive strength fk |
MN/m² |
1,6 |
1,6 |
2,5 |
3,2 |
Gross density class |
0,8 |
0,8 |
0,9 |
1,2 |
|
Calculated weight with DBM |
kN/m³ |
9,0 |
9,0 |
10,0 |
13,0 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,31 |
0,31 |
0,34 |
0,53 |
Thermal resistance RT with DBM |
m²K/W |
4,04 |
4,04 |
3,95 |
3,64 |
U-value*) with DBM |
W/m²K |
0,25 |
0,25 |
0,25 |
0,28 |
Heat storage capacity |
F 180-A |
||||
Fire wall, plastered once |
yes |
yes |
|||
Fire wall, plastered twice **) |
– |
– |
|||
Block requirements per m² |
piece |
8 |
16 |
16 |
16 |
Block requirements per m³ |
piece |
27 |
54 |
54 |
54 |
Mortar requirements per m² |
Liter |
3,6 |
3,6 |
3,6 |
3,6 |
Mortar requirements per m³ |
Liter |
12 |
12 |
12 |
12 |
Working time reference value full masonry |
h/m³(h/m²) |
2,00 |
1,75 |
1,75 |
1,95 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
2,40 |
2,00 |
2,00 |
2,20 |
Packet/palette content |
piece |
30 |
60 |
60 |
60 |
Average weight per block 1) |
kg |
34 |
17 |
19 |
22 |
Article number 40391070 |
36090 |
36076 |
36236 |
36366 |
|
Main field of application 2) |
1, 3 |
1, 3 |
1, 3 |
1, 3 |
Type of block |
KLB flat hollow blocks - Z-17.1-797 |
|||
---|---|---|---|---|
Wall thickness |
cm |
36,5 |
||
Format |
12 DF |
|||
Length |
mm |
247 |
||
Width |
mm |
365 |
||
Height |
mm |
249 |
||
Number of chamber/slot rows |
3 |
|||
Tensile strength class (medium tensile strength) |
(N/mm²) |
2 (2,5) |
4 (5,0) |
6 (7,5) |
Compressive stress σ0 m. DBM |
MN/m² |
0,5 |
0,8 |
1,0 |
Character. Value of compressive strength fk |
MN/m² |
1,6 |
2,5 |
3,2 |
Gross density class |
0,8 |
0,9 |
1,2 |
|
Calculated weight with DBM |
kN/m³ |
9,0 |
10,0 |
13,0 |
Coefficient of thermal conductivity λR with DBM |
W/mK |
0,34 |
0,37 |
0,53 |
Thermal resistance RT with DBM |
m²K/W |
4,14 |
4,06 |
3,76 |
U-value*) with DBM |
W/m²K |
0,24 |
0,25 |
0,27 |
Heat storage capacity |
F 180-A |
|||
Fire wall, plastered once |
yes |
|||
Fire wall, plastered twice**) |
yes |
|||
Block requirements per m² |
piece |
16 |
16 |
16 |
Block requirements per m³ |
piece |
44 |
44 |
44 |
Mortar requirements per m² |
Liter |
4,5 |
4,5 |
4,5 |
Mortar requirements per m³ |
Liter |
12 |
12 |
12 |
Working time reference value full masonry |
h/m³(h/m²) |
1,65 |
1,80 |
2,00 |
Working time reference value categorised. Masonry |
h/m³(h/m²) |
1,90 |
2,10 |
2,30 |
Packet/palette content |
piece |
60 |
60 |
60 |
Average weight per block 1) |
kg |
21 |
23 |
27 |
Article number 40391070 |
36113 |
36243 |
36373 |
|
Main field of application 2) |
1, 3 |
1, 3 |
1, 3 |
*) plastered, inside with 15 mm gypsum light-weight plaster λR = 0.35 W/mK, outside with 100 mm mineral fibre light (WLG 035)
**) plastered, onesided with 15 mm gypsum light-weight plaster, with continous 30mm parting line, filled with min. insulation
- not applicable, not standard
1) higher weight possible depending on weather
2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block