KLB-Flat-Hollow Wall Panel

Light-weight separation wall blocks for non-load-bearing walls

KLB flat hollow wall panels can be used in addition to 8 DF flat solid blocks as light-weight separation blocks for non-load-bearing walls, for partitions or surrounds. KLB-flat-hollow wall panels have the same butt joint gears as the flat-building panel. The load-bearing joint is formed in the hollow wall panels using the thin-bed process, while the butt joint remains free of mortar.

Product data sheet Hollow wall panel

  • 11,5 cm

Block variety/Block type

KLB-Flat-Hollow Wall Panel

Wall thickness

cm

11,5

Format

-

8 DF

Length

mm

497

Width

mm

115

Height

mm

249

Number of chamber/slot rows

-

1

Tensile strength class (medium tensile strength)

(N/mm²)

2 (2,5)

Compressive stress σ0 m. DBM

MN/m²

0,6

Character. Value of compressive strength fk

MN/m²

1,5

Gross density class

-

1,0

Calculated weight with DBM

kN/m³

11

Coefficient of thermal conductivity λR with DBM

W/mK

0,27

Thermal resistance  RT with DBM

m²K/W

0,68

U-value*) with DBM

W/m²K

1,30

Heat storage capacity

kJ/m²K

169

Cool down time

h

24

Fire resistance, α2 = 1.0, plastered

-

F 30-A

Fire wall, plastered once

-

no

Fire wall, plastered twice

-

no

Block requirements per m²

piece

8

Block requirements per m³

piece

70

Mortar requirements per m²

Liter

1,9

Mortar requirements per m³

Liter

20

Working time reference value full masonry

h/m³(h/m²)

(0,43)

Working time reference value categorised. Masonry

h/m³(h/m²)

(0,48)

Packet/palette content

piece

80

Average weight per block 1)

kg

16

Article number 40391070

-

35642

Main field of application 2)

-

4, x

 

1) higher weight possible depending on weather

2) 1 = basement masonry, 2 = exterior masonry, 3 = back-up masonry, 4 = interior masonry, 5 = light-weight separation wall, 6 = statically stressed masonry, 7 = sound insulating masonry, with addition “x” = supplementary block